Xilinx Platform Cable USB: technical reproduction and debug record

Date: 2026-07-15
Host used for the measurements: Windows, WinUSB, Docker Desktop
Repository: openFPGALoader
Target used for the successful test: Spartan-6 XC6SLX45T-FGG484

1. Scope and present result

This document reconstructs the complete debug procedure used to make Xilinx Platform Cable USB devices usable from a native Windows openFPGALoader binary built in Docker. It deliberately distinguishes two electrically similar but firmware-incompatible cable families:

  • the embedded/clone path, cold PID 03fd:000d;
  • genuine Platform Cable USB II/DLC10, cold PID 03fd:0013.

The 000d path is verified end to end. It loads two FX2 images, detects the XC6SLX45T, and programs a 1.48 MB bitstream in approximately 4.1--4.6 seconds.

The 0013 path is verified through both FX2 stages. The first-stage loader was recovered from the installed Xilinx kernel driver and the cable reaches FX2 version 0x0961. On the tested cable, however, the internal programmable logic then reports 0xFFFE. Xilinx iMPACT normally replays xusb_xp2.fmwr through an internal JTAG chain at this point. That last .fmwr interpreter is not yet implemented in openFPGALoader, so a cold genuine DLC10 is not yet an end-to-end standalone result. This is an explicit boundary of the current implementation, not a target-board failure.

The state diagram is available as editable diagrams/xpcu-firmware-state-machine.mmd and rendered diagrams/xpcu-firmware-state-machine.svg.

2. Hardware and software architecture

The cable has three distinct layers which must not be confused:

  1. Windows USB driver binding. WinUSB only gives libusb access to a USB identity. It does not load cable firmware.
  2. Cypress FX2 firmware. This RAM-resident 8051 program implements USB control requests and bulk endpoints. It disappears after complete power removal.
  3. Cable programmable logic. Embedded cables expose a CPLD implementation; Platform Cable USB II contains a Spartan-3A-class internal FPGA/PROM path. It generates the fast JTAG waveforms for the external target connector.

The target FPGA is a fourth, independent JTAG TAP. A successful FX2 version read proves only layers 1 and 2. connected: yes proves that target voltage is sensed; neither result proves valid target TDO.

3. USB identities and firmware matrix

VID:PID openFPGALoader cable name Meaning Correct first image
03fd:000d xilinxPlatformCableUsb_alt Embedded cable cold loader xusb_emb.hex
03fd:0013 xilinxPlatformCableUsb Platform Cable USB II cold loader xusb_xp2_loader.hex
03fd:0008 xilinxPlatformCableUsb_initialized An FX2 image is running Do not upload a boot image blindly

The PID 0008 identity alone does not identify which operational firmware is running. Read request 0x50 first.

File HEX version record Role Tested cable
xusb_emb.hex 0x0404 initial FX2 image cold PID 000d
xusb_xlp.hex 0x0517 accelerated second-stage FX2 image embedded/clone path
xusb_xp2_loader.hex 0x08FD (decimal 2301) initial FX2 image extracted from xusb_xp2.sys cold PID 0013
xusb_xp2.hex 0x0961 (decimal 2401) operational second-stage FX2 image genuine DLC10
xusb_xp2.fmwr proprietary microprogram internal FPGA/PROM overlay/update genuine DLC10

Version byte order

The Intel HEX record at FX2 address 0x19B9 stores the printable four-digit firmware value directly. For example:

:0219B9000517...  -> 0x0517
:0219B9000961...  -> 0x0961

The FX2 GET_VERSION control response returns the low byte first, so host code must decode buf[1] << 8 | buf[0]. Earlier debug output swapped the bytes and called 0x0517 "1705". That display was wrong; it did not describe a different firmware file.

4. Reproducible Windows driver deployment

Build the host-driver packages from the external project:

Set-Location externals\xilinx-usb-driver
.\docker-build.ps1

Extract the Windows ZIP, start an elevated PowerShell in its Windows package, and run:

.\install.ps1
.\detect.ps1

install.ps1 calls the Docker-built wdi-simple.exe once for each PID: 0013, 000d, and 0008. A success message for an absent PID can mean that the package was staged, not that a live device changed driver. After firmware causes PID 0008 to appear, rerun the elevated installer while 0008 is physically present.

Verify with:

Get-PnpDevice -PresentOnly | Where-Object InstanceId -Like 'USB\VID_03FD*'

Device Manager should list the live identity under Universal Serial Bus devices using WinUSB. Xilinx iMPACT normally needs the vendor driver instead; WinUSB intentionally replaces that binding.

5. Docker cross-build and firmware packaging

From the repository root:

.\deploy\scripts\verify-docker-linux-engine.ps1
docker compose -f docker-compose.cross-windows.yml build windows-cross
docker compose -f docker-compose.cross-windows.yml run --rm windows-cross

The cross-build uses an Alpine Linux image. Docker Desktop must use its WSL2 Linux-container engine; Windows-container mode cannot pull alpine:edge.

The executable is installed at:

dist/docker-windows/install/bin/openFPGALoader.exe

Firmware must be copied in deploy/scripts/docker-cross-windows.sh, while the container is running. The Compose /src bind mount does not exist during a Dockerfile RUN layer, so this does not work in alpine.Dockerfile:

RUN cp /src/deploy/ise_programmer_bins/*.hex ...

The runtime script instead copies deploy/ise_programmer_bins/*.hex to:

dist/docker-windows/install/share/openFPGALoader/

Always invoke the built executable by absolute path. Otherwise an older binary on PATH can make a fixed source tree appear broken:

$ofl = (Resolve-Path '.\dist\docker-windows\install\bin\openFPGALoader.exe').Path
& $ofl --scan-usb

6. Recovering the DLC10 loader from the installed Xilinx driver

ISE 14.7 was found at E:\Xilinx\14.7, not at a guessed root directory. The relevant files are:

E:\Xilinx\14.7\ISE_DS\common\bin\nt64\xusb_xp2.sys
E:\Xilinx\14.7\ISE_DS\ISE\data\xusb_xp2.hex
E:\Xilinx\14.7\ISE_DS\ISE\data\xusb_xp2.fmwr
E:\Xilinx\14.7\ISE_DS\ISE\data\xusbcpld.fmwr

Only the operational 0x0961 HEX is installed as a normal file. Loading it directly into cold PID 0013 fails because the missing 2301 loader is embedded in the Windows .sys driver.

Run the repository extractor:

powershell.exe -NoProfile -ExecutionPolicy Bypass `
  -File .\scripts\extract-xusb-loader-from-sys.ps1 `
  -DriverPath 'E:\Xilinx\14.7\ISE_DS\common\bin\nt64\xusb_xp2.sys' `
  -OutputPath '.\deploy\ise_programmer_bins\xusb_xp2_loader.hex'

The explicit process-scoped execution-policy override is needed on hosts which disable direct PowerShell script execution. It does not change the machine-wide policy.

The extractor performs these steps:

  1. validates the DOS MZ and PE signatures;
  2. locates the PE .data section from the section table;
  3. skips the first 0x100 bytes of .data globals;
  4. reads records encoded as uint16_le length, uint16_le address, one zero type byte, length data bytes, and one zero padding byte;
  5. rejects scanner artifacts whose FX2 address range overlaps an accepted record;
  6. requires at least 500 records, an address-zero reset vector, a USB descriptor at 0x0090 containing 03fd:0008, and a two-byte version record at 0x19B9;
  7. writes checksummed Intel HEX and an EOF record.

The tested driver yields 595 firmware records plus the HEX EOF line and version 0x08FD.

7. Cold-start procedures

7.1 Embedded cable, PID 000d -- verified fast path

Fully remove USB and target power, reconnect, then run:

& $ofl --scan-usb
& $ofl -c xilinxPlatformCableUsb_alt --detect -v

The expected state sequence is:

  1. open 03fd:000d;
  2. upload xusb_emb.hex (0x0404) into FX2 RAM;
  3. release FX2 reset and wait for 03fd:0008;
  4. reopen and reload xusb_xlp.hex (0x0517);
  5. wait for 03fd:0008 again;
  6. discover bulk endpoints OUT=0x02, IN=0x86;
  7. select the external chain and prime accelerated transfer;
  8. detect the target TAP.

The accelerator priming sequence reproduced from the reference driver is:

disable -> speed class 0x11 -> enable -> A6 transfer count 2
-> bulk OUT 00 00 -> speed class 0x12 -> restore requested speed

The tested XLP firmware requires the zero-based transfer value number_of_bits - 1. Sending N makes common 32-bit scans a multiple-of-four XPCU CPLD failure case and stalls bulk IN. A USER/SPI readback problem must not be diagnosed by changing this count after the accelerator is working.

Program SRAM with the same cable name and the desired .bit file:

& $ofl -c xilinxPlatformCableUsb_alt --freq 6000000 .\path\design.bit -v

The verified XC6SLX45T IDCODE is 0x04028093 after the normal version-nibble mask. The 1.48 MB test image completed in about 4.1--4.6 seconds.

7.2 Genuine Platform Cable USB II, PID 0013 -- current boundary

After a full power cycle:

& $ofl --scan-usb
& $ofl -c xilinxPlatformCableUsb --detect -v

The expected implemented portion is:

0013 -> xusb_xp2_loader.hex 0x08FD -> 0008
     -> xusb_xp2.hex 0x0961 -> 0008

The observed diagnostic after those successful reloads was:

FX2 version:    0961
CPLD version:   fffe
Const0 version: 03b5
Const1 version: 0004
Const2 version: 200d
status 00 connected: no
TDO stuck at 0

0xFFFE is the decisive value: the cable-internal programmable logic has not been configured. The external Spartan-6 cannot be reached through that state. Do not debug the SP605 ribbon or its IDCODE until the internal overlay loads.

Binary strings in libImpactComm.dll show the vendor sequence uses playxsvf, with fpga, cpld, and cpld2 modes. The 734,080-byte xusb_xp2.fmwr begins with version/comment metadata and a proprietary Xilinx microprogram; it is not a plain FX2 HEX or a directly usable standard XSVF file. USBPcap is installed at C:\Program Files\USBPcap\USBPcapCMD.exe; a capture made while the official driver and iMPACT initialize a cold cable is the next reliable way to recover the exact replay protocol.

7.3 Capturing the remaining official DLC10 initialization

This operation intentionally requires a manual driver transition. Do not run the WinUSB and Xilinx stacks against the cable simultaneously.

  1. Rebind 03fd:0013 and 03fd:0008 to the official ISE 14.7 Xilinx driver.
  2. Remove power from the cable so the next session starts at PID 0013.
  3. In an elevated terminal, identify the USBPcap root-hub interface containing the cable, for example \\.\USBPcap1.
  4. Start a full-length capture before opening iMPACT:
& 'C:\Program Files\USBPcap\USBPcapCMD.exe' `
  -d '\\.\USBPcap1' -A --inject-descriptors `
  -o '.\xpcu-xp2-official-init.pcap'
  1. Open iMPACT and perform exactly one cable connect/detect. Wait until it can see the external chain, then stop USBPcap with Ctrl+C.
  2. In Wireshark use display filter usb.idVendor == 0x03fd. Preserve the enumeration, control transfers, and both bulk endpoints; do not filter the capture at acquisition time.
  3. Record the last GET_VERSION response before the .fmwr traffic, all 0x52 route-selection requests, every 0xA6 transfer length, bulk OUT payload, bulk IN verification data, delays, and the first version response after completion.
  4. Close iMPACT, rebind all three PIDs to WinUSB with install.ps1, and fully power-cycle before testing a replay implementation.

The capture contains copyrighted Xilinx firmware bytes. Keep it as a local reverse-engineering artifact and implement the transport/parser independently; do not add the capture or extracted proprietary payload to a public commit.

8. XPCU USB protocol facts established during debugging

The operational device uses vendor request bRequest=0xB0. Important command values are:

wValue Purpose
0x10 disable
0x18 enable
0x28 set speed; class is carried in wIndex
0x30 synchronous GPIO write
0x38 status/TDO read
0x40 return fixed cable constants
0x50 return FX2/internal-logic version
0x52 select internal/external GPIO/JTAG routing
0xA6 prepare accelerated bulk JTAG transfer

Endpoint discovery should select bulk OUT 0x02 and bulk IN 0x86 from the active interface descriptors rather than assuming them without verification.

On Windows, a newly enumerated device can report configuration zero. The libusb open path therefore reads the active configuration, sets configuration 1 when necessary, claims interface zero, and retries after LIBUSB_ERROR_NOT_FOUND. Handles must be closed even when interface release fails because firmware reload already disconnected the device.

9. Why the slow fallback produced misleading results

FX2 firmware 0x0404 stalls endpoint zero when the accelerated 0xA6 path is used in the tested WinUSB and libusbK configurations. Continuing on the same handle after that stall produced random-looking values such as 0x0C23EA80 and 0xB8B1E8C0. They were transport corruption, not FPGA IDCODEs. Perform a complete power cycle after this failure.

The reliable fallback toggles TCK using synchronous control transfers: two USB writes per JTAG bit, plus reads when TDO is captured. The printed 6 MHz value is the requested cable clock, not effective host throughput. Reaching only 9% of a bitstream after 5--10 minutes was therefore expected and implied a total time approaching an hour.

The fallback also exposed two decoding details:

  • command 0x38 returns the sample following the last shifted bit, so the 0x0404 TDO stream must be compensated by one bit;
  • after a valid device, the tested cable returned trailing word 0x0A001093 instead of the usual all-ones terminator. It is ignored only as a trailing artifact after at least one valid TAP has been accepted.

Before correction, the one-bit-shifted value was 0xA2014049. Restoring the bit alignment yields the valid Spartan-6 family IDCODE 0x04028093 after version masking.

10. Diagnostic environment variables

Variable Meaning
OPENFPGALOADER_XUSB_FIRMWARE override the initial boot HEX
OPENFPGALOADER_XUSB_XLP_FIRMWARE override embedded-cable second stage
OPENFPGALOADER_XUSB_XP2_FIRMWARE override DLC10 second stage
OPENFPGALOADER_XPCU_XLP_UPGRADE=1 force XLP reload
OPENFPGALOADER_XPCU_XP2_UPGRADE=1 force XP2 reload
OPENFPGALOADER_XPCU_SKIP_FIRMWARE_UPGRADE=1 skip any second-stage reload
OPENFPGALOADER_XPCU_SKIP_XLP_UPGRADE=1 skip only XLP reload
OPENFPGALOADER_XPCU_SKIP_XP2_UPGRADE=1 skip only XP2 reload
OPENFPGALOADER_XPCU_CONTROL_BITBANG=1 force the slow control path
OPENFPGALOADER_XPCU_ACCELERATED=1 developer override for accelerated mode
OPENFPGALOADER_FX2_VERBOSE_USB_ERRORS=1 print detailed libusb failures
OPENFPGALOADER_XPCU_CTRL_RETRIES control-request retry count
OPENFPGALOADER_XPCU_CTRL_RETRY_DELAY_MS delay between control retries
OPENFPGALOADER_XPCU_OUT_EP / ..._IN_EP developer endpoint override
OPENFPGALOADER_XPCU_TDO_MASK developer-only TDO mask override
OPENFPGALOADER_XPCU_TRACE_A6=1 print raw accelerated bulk-IN data for alignment debugging

Unset experiments before a normal test:

Get-ChildItem Env:OPENFPGALOADER_XPCU* | Remove-Item
Get-ChildItem Env:OPENFPGALOADER_XUSB* | Remove-Item

11. Failure signatures and decisions

Symptom Interpretation Correct action
--scan-usb shows nothing live PID lacks WinUSB or another process owns it inspect Device Manager; rerun elevated installer for the live PID
remains 000d or 0013 after complete power removal normal cold state select matching cable name and boot HEX
reload reaches 100% then returns to boot PID wrong/incompatible HEX stage restore the proper boot/upgrade pair
LIBUSB_ERROR_NOT_FOUND on claim device has no active configuration use build containing configuration-1 activation/retry
changing invalid IDCODE after A6 timeout endpoint zero is poisoned remove all cable/target power; do not trust that scan
stable 0x0A001093 after valid Spartan-6 word XPCU control-mode trailing artifact use corrected decoder/build
0x0961, internal version 0xFFFE, status 00 DLC10 internal FPGA overlay absent replay xusb_xp2.fmwr; target JTAG is not yet reachable
connected: yes, no TAP target voltage exists but JTAG data is invalid then check power, ground, ribbon, jumpers, TDO and clock

12. Integrity values for this exact reproduction

File Bytes SHA-256
xusb_emb.hex 21,708 C0A7A1F0110D110A2CE2A577EC1EBAF528FD066FEAC54F6FFC9816BE22FAC9D4
xusb_xlp.hex 26,216 03116AB70D74E68204E03F72AD8E45E3A22428CBE612B28DDEBCEC620954270A
xusb_xp2.hex 24,830 F551E3C71EFEE0556B465DC9975D528115F9849EA143F51B5C44D6F3F4F4A9CF
xusb_xp2_loader.hex 23,836 B6E3FAA81C34FAD863D2DDA261E62BBBCA6FAEA4BD6ECF2FF40572BFE71EC0FE
ISE xusb_xp2.sys 19,840 02A762D7BB32CCAA97460ED143AAC00286D961302D97B964C467654F42B1EE6A
ISE xusb_xp2.fmwr 734,080 91B15AAAA52A00E55B633F74D833D0C23061D021EEF4325592C5BA3126E6A75A
ISE xusbcpld.fmwr 90,076 FC1556D3BFE7486E3841F2E1B6DC62400D779ED853EB8D2662BC8943B3B0CFB4

The locally installed and repository xusb_xp2.hex hashes are identical.

13. Minimal regression checklist

For each cable family, start from a complete USB and target power removal.

$ofl = (Resolve-Path '.\dist\docker-windows\install\bin\openFPGALoader.exe').Path
& $ofl --scan-usb
& $ofl -c xilinxPlatformCableUsb_alt --detect -v --freq 6000000
& $ofl -c xilinxPlatformCableUsb_initialized --detect -v --freq 6000000

Record all of these in a test log:

  • PID before and after each reload;
  • selected firmware path and parsed version;
  • endpoint pair;
  • FX2, internal logic, and constant versions;
  • status byte and sensed connection state;
  • requested and real JTAG frequency;
  • whether control or accelerated transfer was selected;
  • every IDCODE and process exit code;
  • bitstream size, elapsed time, and DONE result.

Do not combine results taken before and after a failed 0xA6 request without a power cycle. That was the main source of false conclusions in the original session.

14. External W25Q64 flash investigation

The 5042-9033 target uses an XC6SLX45T-FGG484 and identifies its attached configuration memory in iMPACT as a Winbond W25Q64BV/CV, data width 4.

Do not use test_fw/5042-9033/pab0_top.bit with --bridge. Its BIT header is:

pab0_top.ncd;HW_TIMEOUT=FALSE;UserID=0xFFFFFFFF
6slx45tfgg484

It is a normal application image and contains no openFPGALoader SPI-over-JTAG protocol. Unknown key HW_TIMEOUT is only an unrecognised BIT-header field; it is not the flash failure. With that file loaded, the absent USER interface is reported as legacy SOJ version: 1.000000 and JEDEC detection returns zero.

Omit --bridge so --fpga-part xc6slx45tfgg484 selects the packaged spiOverJtag_xc6slx45tfgg484.bit.gz automatically:

& $ofl -c xilinxPlatformCableUsb_alt `
  --fpga-part xc6slx45tfgg484 --external-flash `
  -f .\test_fw\5042-9033\FW-5042-9033-T30.mcs

The packaged bridge is dated 2024-03-28 and predates the 2025 v2 bridge core. It is legitimately reported as SOJ v1 because it has no USER4 version endpoint. Raw A6 tracing nevertheless proved that its USER1 flash response is also zero:

XPCU A6 RX: bytes=4 data=93800244  # valid FPGA IDCODE stream
XPCU A6 RX: bytes=6 data=000000000000  # USER1 / JEDEC response

Reducing the requested JTAG frequency to 100 kHz (750 kHz was the cable's minimum realised frequency) did not change the zero response. Current bridge source uses an updated v2 protocol and opposite Spartan-6 SPI clock phase, so the next controlled experiment is to rebuild the bridge with ISE 14.7 and test USER4 02.00 plus JEDEC ID before erasing flash.

The local ISE installation can run iMPACT but has no user/WebPACK synthesis license configured. Both Edalize/xtclsh and direct XST stopped before creating a synthesis report. The temporary libPortabilityNOSH.dll compatibility test was reverted and the original installed DLL was hash-verified and restored. Configure a valid Spartan-6 WebPACK license with E:\Xilinx\14.7\ISE_DS\common\bin\nt64\xlcm.exe before rebuilding:

Set-Location .\spiOverJtag
cmd.exe /d /c "call E:\Xilinx\14.7\ISE_DS\settings64.bat && python build.py xc6slx45tfgg484 spi"

Only after --detect -f prints a nonzero JEDEC ID should the MCS write be allowed to proceed.